Applies to:
Cleaning the Safety Relief Valve
To avoid severe burns, do not tamper with safety relief valve while operating fryer. |
To avoid serious personal injury, do not tamper with safety relief valve. Tampering with this valve will void agency approvals and appliance warranty. |
This valve is factory preset to open at 14½ psi. (999 mbar).
-
Remove deadweight cap and deadweight.
-
Use a wrench to loosen the safety relief valve from the pipe elbow, turn counterclockwise to remove.
-
Clean the inside of the pipe elbow with hot water.
NOTE: Turn the safety relief valve towards the rear of the fryer when reinstalling the relief valve.
-
Immerse the safety relief valve in a soapy water solution for 24 hours. Use a 1 to 1 dilution rate. The valve cannot be disassembled. It is factory preset to open at 14-1/2 pounds of pressure (999 mbar). If it does not open or close, it must be replaced.