Replacing the Food Probe Receptacle

crosshead screwdriver
5/16" socket
3/8" socket
![]() |
To avoid electrical shock or property damage, disconnect power before installing or servicing equipment. A qualified technician must perform the service procedures. |
-
Using a crosshead screwdriver, remove the four screws securing the front panel.
-
Pull panel down, pull connectors from the back of it, and remove panel from unit.
-
Using 5/16” socket, remove the 4 nuts securing the control cover and remove cover.
-
Using a 3/8” socket, remove the nuts securing the receptacle bracket, and pull bracket from control panel.
-
Pull connector from the PC board.
-
Install new receptacle assembly in reverse order.