Replacing the Transformer

crosshead screwdriver
![]() |
To avoid electrical shock or property damage, disconnect power before installing or servicing equipment. A qualified technician must perform the service procedures. |
-
Using a crosshead screwdriver, remove the four screws securing the front panel.
-
Lower panel, remove connectors from the back, and remove panel from unit.
-
Label wires to transformer and unplug wires to transformer.
-
Using a crosshead screwdriver, remove the 2 screws securing the transformer and pull transformer from unit.
-
Install new transformer in reverse order and unit is now ready for use.