Adjusting the Drain Valve Actuator

screwdriver
3/32 allen wrench
![]() |
To avoid electrical shock or property damage, disconnect power before installing or servicing equipment. A qualified technician must perform the service procedures. |
![]() |
Only perform this procedure when the unit is cool or severe burns may result. |
Refer to Operating Components for button locations.
-
Loosen allen screw and turn cam lobe slightly in either direction to adjust.
-
Remove two nuts and then turn ¼ counterclockwise to remove pipe between drain valve and trough.
-
Turn ¼ counter clockwise to remove drain valve assembly. Leave harness plugged into actuator to operate from control.
-
Remove four perimeter 3/32 allen screws of actuator switch cover to gain access to cam lobe adjustment screws. Do not let valve just hang from harness.
-
Press and hold Temp and Info buttons at the same time for 10 seconds until Level 3 Programming displays.
-
Enter code 11221122 when prompted.
-
Press Info button five times to get to Tech Mode. Then, press product number 1 button to confirm.
-
Press Temp button three times to get to T‐20 Pumps and Valves. Then, press product number 1 button to confirm.
-
When finished adjusting, valve press product number 2 button with X next to it until main screen displays.
-
Press and hold Program button for six seconds until Level 2 Programming displays.
-
Press Program button five times until Tech Mode displays. Then, enter code 11221122 using product buttons.
-
Press Info button five times to get to T‐21 Pumps and Valves.
-
Press Down Filter button two times to get to valves.
-
Do one of the following:
-
Toggle product button 6 for to open and close drain valve on full vats. Product button 6 on the right will illuminate.
-
Toggle product button 1 to open and close drain valve on split vats. Product button 1 on the left will illuminate.
-
Adjustments can be made to the cam lobes in between opening and closing the valve to get proper adjustment.
Remember a small adjustment can have large effect and to only adjust one cam lobe at a time.
Press and hold the Program button to exit Tech Mode.