Applies to:
Replacing the Drain Rod Microswitch
This component prevents the elements from heating while the drain is open by disrupting the power to the heat contactor.
![]() |
To avoid electrical shock or property damage, move the power switch to OFF and disconnect power. |
Checkout
-
Remove control panel and hinge it down.
-
Referring to the decal on the rear of the control panel, locate P9 connector (left vat-split vat) or P10 connector (full or right vat).
-
Check for normally open circuit between the 2 appropriate pins. If the circuit shows closed, continue with the replacement instructions below.
Replacement
-
Remove right or left side panel, depending upon what side the faulty switch is on.
-
Pull connector from behind control panel area.
-
Using crosshead screwdriver and a 5/16 inch socket, remove the nut and screw securing the switch and remove switch from unit.
-
Remove wires from switch and place on new switch, placing them on the normally open and common terminals.
-
Install new switch in reverse order.