Applies to:

Replacing the JIB Pump

This pump keeps the vats filled and is used in the Oil Guardian™ process.

To avoid electrical shock or property damage, move the power switch to OFF and disconnect power.

  1. Remove the right side panel.

  2. Using a 1 inch wrench, loosen fitting on right side of pump.

  3. Remove the hose from the pump.

  4. Remove the 4 bolts securing the bottom of pump.

  5. Disconnect the wires in the rear of the pump and pull assembly from fryer.

  6. Pull fittings from faulty pump and attach the fittings to the new pump in the same orientation.

  7. Install new pump assembly in fryer, in reverse order and then reconnect power to fryer.