Applies to:
Replacing the JIB Pump
This pump keeps the vats filled and is used in the Oil Guardian™ process.
![]() |
To avoid electrical shock or property damage, move the power switch to OFF and disconnect power. |
-
Remove the right side panel.
-
Using a 1 inch wrench, loosen fitting on right side of pump.
-
Remove the hose from the pump.
-
Remove the 4 bolts securing the bottom of pump.
-
Disconnect the wires in the rear of the pump and pull assembly from fryer.
-
Pull fittings from faulty pump and attach the fittings to the new pump in the same orientation.
-
Install new pump assembly in fryer, in reverse order and then reconnect power to fryer.