Replacing the Gas Valve Solenoid Coil
Prior to replacing the solenoid coil, perform the gas valve troubleshooting. If the issue persists, then perform the following troubleshooting:
-
Ensure vent hole on pressure regulation stem on gas valve is clear.
-
Ensure voltage to the coil is 24VAC and valve remains closed.
-
Disconnect coil wires and then test voltage is 24VAC.
If voltage does not read 24VAC after performing all steps listed above, replace the coil.
Replacing
![]() |
To avoid electrical shock or property damage, move the power switch to OFF and disconnect power. |
-
Remove electrical power and gas supply to unit.
-
Use a crosshead screwdriver to remove the two screws in the control board.
-
Lower the control board and disconnect transformer harness.
-
If present, remove the inner heat shield.
-
Using a flat blade screwdriver, remove e-clip from solenoid coil.
-
Remove solenoid coil from gas valve.
-
Place new solenoid coil on gas valve stem.
-
Align e-clip on solenoid coil and apply pressure to snap into place.
NOTE: You may need to apply pressure with a tool such as a flat blade screwdriver.