Replacing the Pilot
![]() |
To avoid electrical shock or property damage, move the power switch to OFF and disconnect power. |
-
Remove electrical power supplied to the unit.
-
Lower the control board.
-
Remove the flame sensor wire from the red insulated terminal(1).
-
Remove the two screws securing the pilot to the burner assembly (2). The right hand screw will have the ground wire.
-
Disconnect the pilot wire (3) located in the orange rubber sleeve.
-
Using a 7/16 inch wrench, loosen the pilot tube from the pilot.
-
Replace pilot in reverse order.
-
When screwing the pilot back to the burner assembly, be sure to connect the ground wire to the right hand screw.