Applies to:
Replacing the Temperature Probe (Electric)

screwdriver
1/2 inch wrench
The temperature probe relays the actual oil temperature to the control board. If it becomes disabled, "E06" will show in the display. Also, if the oil temperature is out of calibration by more than 10°F or C° the probe should be replaced. An Ohm check can be performed as well. See chart.
![]() |
To avoid electrical shock or property damage, move the power switch to OFF and disconnect power. |
-
Remove electrical power supplied to the unit.
-
Drain oil from the vat.
-
Remove screws securing rear cover of fryer.
-
Remove rear cover.
-
Use a 1/2 in. wrench to remove the nut on the compression fitting.
-
Disconnect and remove the probe from the vat.
-
Place the nut and new ferrule on the new probe and insert the probe into the compression fitting until it extends 1 in. or 2.54 cm into the vat.
-
Reconnect new probe onto wires, replace rear cover and fryer is now ready for use.
Related Content
Replacing the Heating Contactors (Electric)
Replacing the Heating Elements (Electric)
Replacing the High Temperature Limit Control (Electric)
Replacing the Flame Sensor / Pilot / Ignitor Assembly (Gas)
Replacing the High Temperature Limit Control (Gas Units)
Replacing the Temperature Probe (Gas)
Replacing the Gas Control Valve
Troubleshooting the OFG 34X Fryer Stuck in Ignition Loop
Reference