Applies to:
Replacing the Power Switch
![]() |
To avoid electrical shock or property damage, move the power switch to OFF and disconnect power. |
-
Remove electrical power supplied to the unit.
-
Remove the control panel.
-
Label and remove wires from the switch.
-
With a test instrument check across the terminals of the switch with the switch in the ON position and the circuit should be closed.
-
In the OFF position, the circuit should be open. If the switch checks defective, replace by continuing with this procedure.
-
With control panel removed, and the wires off the switch, push in on tabs on the switch to remove form panel.
-
Replace with new switch.
-
Reconnect wires to switch.
-
Replace the control panel.
-
Unit is ready for operation.
Related Content
Replacing the Complete Control Panel
Replacing the Control and I/O Boards
Replacing the Speaker Assembly
Troubleshooting an Unresponsive Control Displaying 8's
Reflashing the CFA ARM-Based Control
Replacing the Heating Contactors (Electric)
Replacing the Heating Elements (Electric)
Replacing the High Temperature Limit Control (Electric)
Replacing the Temperature Probe (Electric)
Replacing the Flame Sensor / Pilot / Ignitor Assembly (Gas)
Replacing the High Temperature Limit Control (Gas Units)
Replacing the Temperature Probe (Gas)
Replacing the Gas Control Valve
Troubleshooting the OFG 34X Fryer Stuck in Ignition Loop
Reference