Applies to:
Testing Thermostat
![]() |
To avoid electrical shock or property damage, move the power switch to OFF and disconnect power. |
If the thermostat fails to work properly, perform the following checks before replacing the thermostat
-
Remove electrical power supplied to the fryer.
-
Remove the control panel.
-
With an ohmmeter or continuity light, check for continuity.
-
To check continuity on a standard temperature thermostat, check between terminals 52 and 53. Move the temperature knob from off to maximum.
-
At off position, the circuit should be open. At maximum, the circuit should be closed.