Applies to:
Replacing the Main Power Switch
Main Power Switch
![]() |
To avoid electrical shock or property damage, move the power switch to OFF and disconnect power. |
The Main Power switch is a three way switch with a center OFF position. With the switch in POWER position, the fryer will operate. With the switch in the PUMP position, the filter pump will operate but the heating unit will not.
Continuity Check Procedure
Continuity Check Procedure - Off Position
Test Points | Results |
#60 to #59 then #60 to #67 | Open circuit |
#61 to #58 then #61 to #66 | Open circuit |
#62 to #57 then #62 to #65 | Open circuit |
#63 to #56 then #63 to #64 | Open circuit |
#60 to #61 | Closed circuit |
#62 to #63 | Closed circuit |
Continuity Check Procedure - Power Position
Test Points | Results |
#60 to #59 | Closed circuit |
#61 to #58 | Closed circuit |
#62 to #57 | Closed circuit |
#63 to #56 | Closed circuit |
Continuity Check Procedure - Pump Position
Test Points | Results |
#60 to #67 | Closed circuit |
#61 to #66 | Closed circuit |
#62 to #65 | Closed circuit |
#63 to #64 | Closed circuit |
Replacement
-
Remove control panel.
-
Label wires at the Main Power switch and disconnect wires at switch.
-
Remove faulty switch and install new switch.
-
Reconnect wires to switch in the same position as noted on the labels.
-
Replace control panel
Related Content
Replacing the Indicator Lights
Electronic C2000 Simple Control Retrofit Kit
RLink programming instructions
PFE 500/PFG 600 Hybrid Control Installation Instructions
PFE 500/PFG 600 Wi-Fi Verification and Troubleshooting Instructions
FAST Control Installation Instructions
2nd Generation Radio for SMS: Hardware Installation
2nd Generation Radio for SMS: Software Update
FM08-748 2nd Generation Radio for SMS: Troubleshooting
Instructions for Fryer Control Replacement Kits
SMS 20 Auto Polish Programming Instructions
Troubleshooting the SMS 20 Control Countdown
Troubleshooting the SMS Control Online Projection System (OPS) Connection
Troubleshooting the Filter Count Not Reducing with Each Drop
Replacing the High Temperature Limit Control
Calibrating The Standard Single Stage Thermostat
Replacing the Temperature Probe
Replacing the Heating Elements
Replacing the Heating Contactors
Temperature Probe Gauge Instructions
Troubleshooting an E-10 High Limit Trip
Troubleshooting a W-7 Low Amperage
Troubleshooting an E-92 Error Code
Troubleshooting Oil Melting or Heating Slowly
Reference