Replacing the Main Power Switch

Main Power Switch

To avoid electrical shock or property damage, move the power switch to OFF and disconnect power.

The Main Power switch is a three way switch with a center OFF position. With the switch in POWER position, the fryer will operate. With the switch in the PUMP position, the filter pump will operate but the heating unit will not.

Continuity Check Procedure

Continuity Check Procedure - Off Position

Test Points Results
#60 to #59 then #60 to #67 Open circuit
#61 to #58 then #61 to #66 Open circuit
#62 to #57 then #62 to #65 Open circuit
#63 to #56 then #63 to #64 Open circuit
#60 to #61 Closed circuit
#62 to #63 Closed circuit

Continuity Check Procedure - Power Position

Test Points Results
#60 to #59 Closed circuit
#61 to #58 Closed circuit
#62 to #57 Closed circuit
#63 to #56 Closed circuit

Continuity Check Procedure - Pump Position

Test Points Results
#60 to #67 Closed circuit
#61 to #66 Closed circuit
#62 to #65 Closed circuit
#63 to #64 Closed circuit

Replacement

  1. Remove control panel.

  2. Label wires at the Main Power switch and disconnect wires at switch.

  3. Remove faulty switch and install new switch.

  4. Reconnect wires to switch in the same position as noted on the labels.

  5. Replace control panel

Related Content

Replacing the Indicator Lights

Lowering the Control

Replacing the Timing Control

Replacing the Fuse Holder

Auxillary Buzzer Kit

SMS Retrofit kit

Electronic C2000 Simple Control Retrofit Kit

RLink programming instructions

PFE 500/PFG 600 Hybrid Control Installation Instructions

PFE 500/PFG 600 Wi-Fi Verification and Troubleshooting Instructions

FAST Control Installation Instructions

2nd Generation Radio for SMS: Hardware Installation

2nd Generation Radio for SMS: Software Update

FM08-748 2nd Generation Radio for SMS: Troubleshooting

Instructions for Fryer Control Replacement Kits

SMS 20 Auto Polish Programming Instructions

CFA PFE 500 Hybrid Wi-Fi Status Check

Troubleshooting the SMS 20 Control Countdown

Troubleshooting the SMS Control Online Projection System (OPS) Connection

Troubleshooting the Filter Count Not Reducing with Each Drop

Replacing the High Temperature Limit Control

Replacing the Thermostat

Testing Thermostat

Calibrating The Standard Single Stage Thermostat

Replacing the Temperature Probe

Replacing the Transformer

Replacing the Heating Elements

Replacing the Heating Contactors

Temperature Probe Gauge Instructions

Troubleshooting an E-10 High Limit Trip

Troubleshooting a W-7 Low Amperage

Troubleshooting an E-92 Error Code

Troubleshooting Oil Melting or Heating Slowly

Reference

Specifications

Error Codes

Error Codes for Chick-fil-A

PFE 5XX C7000 Error Codes

Wiring Diagrams

PFE 500 and 561 Inspection and Planned Maintenance

PFE 500 KFC Annual Inspection Certification