Replacing the Temperature Probe
|
To avoid electrical shock or property damage, move the power switch to OFF and disconnect power. |
The temperature probe relays the actual oil temperature to the control. If it becomes disabled, “E-6” shows in the display. If the temperature is out of calibration more than10° F, or 10° C, the temperature probe should be replaced.
-
Remove electrical power supplied to the fryer.
-
Drain the oil from the vat.
-
Remove the control panel.
-
Use a 1/2 in. wrench, remove the nut on the compression fitting.
-
Remove the temperature probe from the vat.
-
Tighten the compression nut hand tight and then a half turn with a wrench.
-
Connect new temperature probe to PC board and replace control panel.
-
Replace oil and turn power on.
Related Content
Replacing the High Temperature Limit Control
Calibrating The Standard Single Stage Thermostat
Replacing the Heating Elements
Replacing the Heating Contactors
Replacing the Main Power Switch
Temperature Probe Gauge Instructions
Troubleshooting the PFE 500 and 561 E-5 Oil Overheating Error Code
Troubleshooting PFE 561 E-6 Temperature Probe Error Code
Troubleshooting PFE 561 E-10 High Limit Error Code
Troubleshooting PFE 500 and 561 E-26 Heat Amps Locked On Error Code
Troubleshooting an E-92 Error Code
Troubleshooting PFE 561 E-92 24V Current Limiter (Fuse) Trip Error Code
Troubleshooting Oil Melting or Heating Slowly
Troubleshooting PFE 500 W-1 Low Voltage Warning
Troubleshooting PFE 500 W-2 Slow Heating Warning
Troubleshooting PFE 500 W-3 Was Not Ready Warning
Troubleshooting PFE 500 W-4 Slow Cooking Warning
Troubleshooting PFE 500 W-5 Slow Cooking Warning
Troubleshooting PFE 500 W-6 Slow Cooking Warning
Troubleshooting PFE 500 W-9 Discard Product Warning
Reference