Replacing the JIB Pump Motor
Wire cutter
7/16” wrench
Crosstip screwdriver
zip ties
towels
153417-001 120 VAC JIB Pump Motor
153417-002 230 VAC JIB Pump Motor
Estimated Time
1 hour
                                                                             
                                                                         | 
                                                                        
                                                                             To avoid electrical shock or property damage, disconnect power before installing or servicing equipment. A qualified technician must perform the service procedures.  | 
                                                                    
- 
                                                                    
Disconnect power from the fryer.
                                                                     - 
                                                                    
Remove the three screws below the front access cover and lower (this is the cover below the display boards). Locate the OMS board behind control #2 on two and three vat units and behind control #3 on four vat units.
 - 
                                                                    
Disconnect the wire harness from connector P9 at the OMS board. Follow the harness from P9 to the JIB pump and cut all wire ties.
                                                                     - 
                                                                    
From the rear of the fryer, pull the blue quick disconnect tab out from both the inlet and outlet side of the JIB pump.
 - 
                                                                    
Pull out both the inlet and outlet fittings and wipe up excess oil with towel.
 - 
                                                                    
Remove two 7/16 inch nuts from mounting plate at bottom of JIB pump motor.
 - 
                                                                    
Remove JIB pump motor.
 - 
                                                                    
Install new JIB pump motor with two 7/16 inch nuts.
 - 
                                                                    
Connect inlet and outlet fittings and secure by pressing in on blue disconnect tabs until they snap into place.
 - 
                                                                    
Route wiring harness, plug into the OMS board and secure with zip ties.
 - 
                                                                    
Secure access panel to the closed position with three cross head screws.
 - 
                                                                    
Restore power to unit.
 - 
                                                                    
Test new JIB pump motor by:
- 
                                                                            
Tap the menu icon in the lower left corner of the display to open the settings menu.
 - 
                                                                            
Tap Oil & Filter.
 - 
                                                                            
Tap Fill Vat.
 - 
                                                                            
Tap JIB.
 - 
                                                                            
Tap and hold FILL for several seconds to fill the vat from the JIB.
 
 - 
                                                                            
 - 
                                                                    
Once completed, tap DONE to exit.
 
Related Content
Troubleshooting the Check JIB Message
Selector Valve Port Configurations
Replacing the Selector Valve Motor
Replacing the Port Selector Valve Assembly
Troubleshooting a Drain Pan Switch Failure
Troubleshooting a Change Pad Reminder XX hrs. Error
Troubleshooting an E-82D Selector Valve Error
CE Filter Motor Cover Retrofit