Applies to:
Replacing the Vacuum Switch
![]() |
To avoid electrical shock or property damage, move the power switch to OFF and disconnect power. |
-
Remove electrical power supplied to the unit.
-
Remove the control panel.
-
Remove the 2 screws securing the switch to the heat shield.
-
Remove the air hose form the air switch.
-
Label and remove wires from air switch.
-
Install new vacuum switch.