Applies to:

Replacing Pressure Gauge

To avoid personal injury or property damage, before starting this procedure, move the main power switch to the off position. Disconnect the main circuit breakers at the circuit breaker box or unplug service cord from wall receptacle. Turn off the main gas supply to the fryer and disconnect and cap the main supply line to fryer, or possible explosion could result.

Pressure Gauge

The pressure gauge can be re-calibrated, if out of adjustment.

Calibration Steps

  1. Remove the rim and glass

  2. If the indicating hand shows a pressure or vacuum reading when it should stand at "0", turn the re-calibrator screw in the same direction in which the indicating hand is to be moved until the hand stands at proper "0" position.

  3. Replace rim and glass.

Cleaning Steps

  1. Remove gauge and check inside the pipe fittings from deadweight body. Make certain fittings are clean and open.

  2. Clean and reinstall gauge.