Converting the HMR from Full to Self Service
crosshead screwdriver
5/16” socket
The HMR can be converted in the field but it may not work fully as designed. Henny Penny does not recommend or guarantee this conversion.
|
To avoid electrical shock or property damage, move the power switch to OFF and disconnect power. |
-
Remove the crosshead screws securing the bottom, rear cover and let hinge down.
-
Using 5/16” socket, remove nuts securing the fan.
-
Cut the cooling fan wires and remove the cooling fan from the unit.
-
Fully remove or cap off each wire to fan.
-
Replace the opening left by fan needs to be filled with a new top cover and blank panel.
-
Mount the probe that was installed in one of the fan assemblies in new location.
-
Install the plate for the probe in the space with the fan it was previously installed.
-
Disconnect the water heater. It can be left in place.
-
Remove or cap the wires.
-
Replace the canopy glass with the appropriate self-service style glass.
-
Install appropriate gas rams to match the new style glass.