Error Codes
|
DISPLAY |
CAUSE |
PANEL BOARD CORRECTION |
|---|---|---|
|
“E-4” |
Control board overheating |
Turn switch to OFF position, then turn switch back to ON; if “E-4” continues, the board is getting too hot; check for signs of overheating behind the control panel; once panel cools down the controls should return to normal; if “E-4” persists, have control panel replaced |
|
“E-5” |
Oil overheating |
Turn switch to OFF position, then back to ON; if “E-5” continues, the heating circuits and temperature probe should be checked; once the unit cools down, the controls should return to normal; if “E-5” persists, have control panel replaced |
|
“E-41” |
Programming failure |
Turn switch to OFF position, then back to ON; if display shows “E-41”, the control should be re- initialized (See Programming Section) if the error code persists, have control panel replaced |
Related Content
Information about the 580 and 582 Fryers
Installing the 580 and 582 Fryers
Operating the 580 and 582 Fryers
Programming the 580 and 582 Fryers
Troubleshooting the 580 and 582 Fryers
Cleaning the Safety Relief Valve
Calibrating and Cleaning the Pressure Gauge
SMS Control Special Programming
Testing and Replacing the Power/Pump Switch
Troubleshooting the PFE 580 or 582 E-41 Control Programming Lost Error Code
Replacing the High Temperature Limit Control
Testing and Replacing the Fuse Holders
Replacing the Heating Elements
Replacing the Temperature Probe
Troubleshooting the PFE 580 or 582 E-5 Oil Overheating Error Code
Troubleshooting the PFE 580 or 582 E-6 Temperature Probe Error Code
Troubleshooting the PFE 580 or 582 No Heat Error Code
Replacing the Drain Microswitch
Replacing the Lid Counterweight Cables
Adjusting the Lid Magnet Plate
Replacing the Nylatron Slides (Cam Slide Filler)
Reference