Error Codes
DISPLAY |
CAUSE |
PANEL BOARD CORRECTION |
---|---|---|
“E-4” |
Control board overheating |
Turn switch to OFF position, then turn switch back to ON; if “E-4” continues, the board is getting too hot; check for signs of overheating behind the control panel; once panel cools down the controls should return to normal; if “E-4” persists, have control panel replaced |
“E-5” |
Oil overheating |
Turn switch to OFF position, then back to ON; if “E-5” continues, the heating circuits and temperature probe should be checked; once the unit cools down, the controls should return to normal; if “E-5” persists, have control panel replaced |
“E-41” |
Programming failure |
Turn switch to OFF position, then back to ON; if display shows “E-41”, the control should be re- initialized (See Programming Section) if the error code persists, have control panel replaced |
Related Content
Information about the 580 and 582 Fryers
Installing the 580 and 582 Fryers
Operating the 580 and 582 Fryers
Programming the 580 and 582 Fryers
Troubleshooting the 580 and 582 Fryers
Cleaning the Safety Relief Valve
Calibrating and Cleaning the Pressure Gauge
SMS Control Special Programming
Testing and Replacing the Power/Pump Switch
Replacing the High Temperature Limit Control
Testing and Replacing the Fuse Holders
Replacing the Heating Elements
Replacing the Temperature Probe
Replacing the Drain Microswitch
Replacing the Lid Counterweight Cables
Adjusting the Lid Magnet Plate
Replacing the Nylatron Slides (Cam Slide Filler)