Applies to:

Replacing the Gas Burner Assembly

The gas model fryer has a gas burner assembly consisting of a burner casting,

orifices, thermocouple, pilot holder, and main gas control valve.

To avoid personal injury or property damage, before starting this procedure, move the main power switch to the off position. Disconnect the main circuit breakers at the circuit breaker box or unplug service cord from wall receptacle. Turn off the main gas supply to the fryer and disconnect and cap the main supply line to fryer, or possible explosion could result.

To avoid personal injury or explosion, check piping and fittings for gas leaks. Leaking gas may cause an explosion.

Check for leaks per Gas Supply. If a leak is detected, shut off gas control valves and repair leak.

NOTICE -

If converting from natural gas to propane gas or from propane gas to natural gas, conversion must be done by a qualified service technician.

NOTICE -

To avoid product damage, do not drop or impact the pilot orifice. The burner will not operate without orifice.

Fire or Explosion Risk

To avoid personal injury and/or property damage, do not use lighted match or open flame to text for gas leaks.

  1. Remove the control panel.

  2. Place the control panel back in upright position, in the metal flanges.

  3. Remove wires from the gas control valve.

  4. Disconnect gas supply line from the connector at control valve.

  5. Loosen the two screws on the heat shield deflector, on the firebox and flue assembly and raise the deflector to its highest position.

  6. Re-tighten screws to hold the heat shield deflector in the high position.

  7. Turn the filter valve rod to the OPEN position.

  8. Remove the U-bolt form rinse hose bracket.

  9. Remove entire gas burner assembly, by lifting and pulling toward front of fryer.

  10. Replace the thermocouple.

  11. Repair or replace gas control valve.

  12. Replace orifices as required. Note, there are 23 brass orifices and 1 stainless steel orifice. The stainless steel orifice is to be mounted adjacent to the pilot light.

  13. Make other repairs or replacements as required.

  14. Install entire gas burner assembly

  15. Install u-bolt to rinse hose bracket and gas line.

  16. Turn the filter valve handle to the CLOSED position.

  17. Loosen the two screws which are holding the heat shield deflector in the high position, and lower it to the normal operating position.

  18. Tighten the two screws on the heat shield.

  19. Connect gas supply line to the gas control valve connector.

  20. Install the wires onto gas control valve.

  21. Remove control panel and install it in the slot above door.

  22. Connect the gas control valve wires to the thermostat and high temperature limit control as labeled.

  23. Install control panel.

  24. Uncap and reconnect the main gas supply on the fryer. Turn on the main gas supply.

  25. Connect the service cord to the wall receptacle, or close circuit breakers.

  26. Relight the gas pilot.