Applies to:

Gas Conversion

Conversions must be performed by a Henny Penny authorized service technician.

Gas model fryers are factory available for either natural gas or propane gas. Factory conversion kits for natural gas and propane gas are available that require burner jets, pilot jet, and regulator assembly to be changed, see for kit identification.

Service Hints

On natural gas installation, the gas pressure regulator on the automatic gas control valve is factory set to 3.5 inch water column.

On propane gas installation, the gas pressure regulator on the automatic gas control valve is factory set to 10.0 inch water column.

After converting the fryer, turn on the gas supply and check for leaks. A simple method is to brush all connectors with soapy water, and watch for bubbles which indicate escaping gas.

Fire or Explosion Risk

To avoid personal injury and/or property damage, do not use lighted match or open flame to text for gas leaks.

Maintenance

To avoid personal injury or property damage, before starting this procedure, move the main power switch to the off position. Disconnect the main circuit breakers at the circuit breaker box or unplug service cord from wall receptacle. Turn off the main gas supply to the fryer and disconnect and cap the main supply line to fryer, or possible explosion could result.

  1. To convert from one type of gas to another, turn the gas valve knob to the OFF position.

  2. Close the gas control valve and disconnect fryer supply line.

  3. Remove gas control valve and burner assembly.

  4. Remove the burner orifices (24 each), and replace with orifices in gas conversion kit.

  5. Remove the pilot holder assembly and replace with one from the kit.

  6. Remove the gas control valve manufacturer's instructions from the envelope containing the regulator spring, and follow directions for converting the gas control valve. Outlet pressure is stated on the enclosed label.

  7. Attach the pressure sensitive data plate label to the data plate, covering up the old rating and pressure information.

  8. Install converted gas control valve and burner assembly.

  9. Connect the gas supply to the fryer.

  10. Ensure the power switch is in the OFF position, gas control valve in the OFF position.

  11. Connect the electrical power to the fryer.

  12. Check for gas leak at supply line.

  13. Turn the gas control valve on and turn the gas control valve to PILOT position.

  14. Check for gas leak at the gas control valve and main gas valve.

  15. If no leak is detected with the gas valve knob at pilot, depress the dial and light the pilot burner.