Applies to:

Direct connect retrofit PFG-600

Kit number

14370

Estimated Time

30 Minutes to 1 hour

  1. Note before starting, This system is designed to operate using only a 1/2 hp pump motor. If the motor data plate reads 1/3 hp then replace with a 1/2 hp pump motor.

  2. Disconnect power to fryer and allow fryer to cool.

  3. Remove the filter rinse pipe from the fryer.

  4. Remove the 3/8 in. 90° elbow and close nipple from the fryer.

  5. Remove the screw from the front bracket.

  6. Install the new bracket.

  7. Reinstall screw into existing hole, drill 1/8 in. pilot hole in the other hole of the bracket.

  8. Install a self-drilling screw with the extra screws provided from the kit.

  9. Install the new hose assembly to the 11 1/2 in. nipple.

  10. Install the spring onto the rod.

  11. Install the handle in the hole previously occupied by the filter rinse pipe. Ensure the orientation of the handle is that it is aligned vertically when the valve is closed.

  12. Place red sleeve onto handle portion of rod.

  13. Install a cotter pin to secure the handle to the valve.

  14. Test the red handle of the direct connect and verify that the spring allows the valve to open completely by hand an close completely using the tension of the spring. If necessary adjust the tension of the spring by placing the end of the spring into a different slot on the bracket.

  15. Install the male quick-disconnect to the manifold attached to the wall behind the fryers.

  16. Connect the hose to the discard line.

  17. Install the bracket only if no existing bracket is on the fryer to secure the filter drain rod.

Related Content

Replacing the High Temperature Limit Control

Checking the Temperature Probe Calibration for Chick-fil-A

Replacing the Temperature Probe

Replacing the Transformer

Testing Thermostat

Calibrating The Standard Single Stage Thermostat

Replacing the Thermostat

Replacing the Gas Burner Assembly

Replacing the Thermocouple

PFG 600 Gas Control Valve

Gas Conversion

Replacing the Main Power Switch

PFG 600 SSI Fryers Gas Valve Replacement Kit

Installing the Spark Ignition

Mounting the Thermostat

Direct connect retrofit PFG 600

PFG 600 Ignition Module Retrofit Kit

Temperature Probe Gauge Instructions

Installing the Pump Seal Kit

Filter Pan Dolly Assembly

Auxillary Buzzer Kit

Direct connect oil system operating instructions

SMS Retrofit kit

Electronic C2000 Simple Control Retrofit Kit

Spring Tool Operation Kit

Installation of PFG 600 and PFG 600 SSI FM07-366 Electromechanical to C1000 Retrofit

C2000 Operating instructions

PFG 600 SSI Electronic C1000 to C8000 Retrofit Kit

4 Head PFE 500/ PFG 600 Removing the Lid

RLink programming instructions

Pressure Assist Kit Installation

PFE 500/PFG 600 Wi-Fi Verification and Troubleshooting Instructions

PFE 500/PFG 600 Hybrid Control Installation Instructions

FAST Control Installation Instructions

2nd Generation Radio for SMS: Hardware Installation

2nd Generation Radio for SMS: Software Update

FM08-748 2nd Generation Radio for SMS: Troubleshooting

Crossarm Repair Kit

Instructions for Fryer Control Replacement Kits

SMS 20 Auto Polish Programming Instructions

PFG 600 Relay Retrofit

SAE Thread Filter Pump Installation

Pre VA SAE Thread Filter Pump Installation

Hybrid Control and Wi-Fi Installation

Reference

PFG 600 Inspection and Planned Maintenance

Wiring Diagrams

Error Codes

PFG 600 KFC Annual Inspection Certification