Applies to:
Replacing the JIB Pump Motor

Wire cutter
7/16” wrench
Crosstip screwdriver
zip ties
towels

153417-001 120 VAC JIB Pump Motor
153417-002 230 VAC JIB Pump Motor
Estimated Time
1 hour
![]() |
To avoid electrical shock or property damage, disconnect power before installing or servicing equipment. A qualified technician must perform the service procedures. |
-
Disconnect power from the fryer.
-
Remove the three screws below the front access cover and lower (this is the cover below the display boards). Locate the OMS board behind control #2 on two and three vat units and behind control #3 on four vat units.
-
Disconnect the wire harness from connector P9 at the OMS board. Follow the harness from P9 to the JIB pump and cut all wire ties.
-
From the rear of the fryer, pull the blue quick disconnect tab out from both the inlet and outlet side of the JIB pump.
-
Pull out both the inlet and outlet fittings and wipe up excess oil with towel.
-
Remove two 7/16 inch nuts from mounting plate at bottom of JIB pump motor.
-
Remove JIB pump motor.
-
Install new JIB pump motor with two 7/16 inch nuts.
-
Connect inlet and outlet fittings and secure by pressing in on blue disconnect tabs until they snap into place.
-
Route wiring harness, plug into the OMS board and secure with zip ties.
-
Secure access panel to the closed position with three cross head screws.
-
Restore power to unit.
-
Test new JIB pump motor by:
-
Tap the menu icon in the lower left corner of the display to open the settings menu.
-
Tap Oil & Filter.
-
Tap Fill Vat.
-
Tap JIB.
-
Tap and hold FILL for several seconds to fill the vat from the JIB.
-
-
Once completed, tap DONE to exit.