Applies to:

Replacing the Pilot / Ignitor Assembly

To avoid electrical shock or property damage, move the power switch to OFF and disconnect power.

The Henny Penny open fryer (gas) has electronic spark ignition that lights a standing pilot. The gap between the spark electrode and the pilot hood should be set at 1/8 of an inch.

  1. Remove electrical power supplied to the unit.

  2. Remove the control panel.

  3. Disconnect the pilot gas line fitting at the pilot assembly with a 1/2 in. wrench.

  4. Use a crosstip head screwdriver to remove the two screws securing the pilot assembly to the mounting bracket.

  5. Remove the flame sensor wire from the flame sensor.

  6. Follow the wire from the spark ignitor back to the module, and remove wire from module.

  7. After removing assembly from unit, pull the flame sensor out of the bracket.

  8. Insert flame sensor into new pilot assembly.

  9. Reinstall the new pilot assembly in reverse order. Ensure to not cross thread the pilot gas line fitting.

  10. Label wires at the Main Power switch and disconnect wires at switch.

  11. Remove faulty switch and install new switch.

  12. Reconnect wires to switch in the same position as noted on the labels.

  13. Replace control panel

Related Content

Replacing the Blower Motor Assembly

Replacing Heating Contactors (Electric Only)

Replacing Heating Elements (Electric Only)

Replacing the High Limit Temperature Control (Electric Units)

Replacing the High Temperature Limit Control (Gas Units)

Replacing the Flame Sensor (Gas Units)

Replacing the Ignitor Module

Replacing the Gas Control Valve Assembly

Replacing the Temperature Probe

Replacing the Power Switch

Troubleshooting the OFG 32X Fryer Stuck in Ignition Loop

Troubleshooting the OFG 32X Fryer E-4 Control Overheating Error Code

Troubleshooting the OFE and OFG 32X Fryer E-5 Oil Overheating Error Code

Troubleshooting the OFE and OFG 32X Fryer E-6 Temperature Probe Error Code

Troubleshooting the OFE and OFG 32X Fryer E-10 High Limit Error Code

Troubleshooting the OFE and OFG 32X Fryer E-20A Fan Sensor Stuck Closed Error Code

Troubleshooting the OFG 32X Fryer E-20B Pressure Switch Stuck Error Code

Troubleshooting the OFG 32X Fryer E-20D Ignition Failure Error Code

Troubleshooting the OFE 32X Fryer E-26 Heat Amps Locked Error Code

Troubleshooting the OFE and OFG 32X Fryer E-92 24V Circuit Overload Error Code

Troubleshooting the OFE 32X Fryer W-1 Low Voltage Warning

Troubleshooting the OFE 32X Fryer W-2 Slow Heating Warning

Troubleshooting the OFE 32X Fryer W-3 Was Not Ready Warning

Troubleshooting the OFE 32X Fryer W-4 Slow Cooking Warning

Troubleshooting the OFE 32X Fryer W-5 Slow Cooking Warning

Troubleshooting the OFE 32X Fryer W-6 Slow Cooking Warning

Troubleshooting the OFE 32X Fryer W-7 Low Amps Warning

Troubleshooting the OFE 32X Fryer W-9 Discard Product Warning

Reference

Specifications

Error Codes