Applies to:

Troubleshooting the OFG 32X Fryer Stuck in Ignition Loop

Overview

The OFG fryer may go through the entire ignition process and light the main burn and immediately restart to the beginning sequence. If this process keeps repeating indefinitely, follow the troubleshooting procedure to end the loop.

Troubleshooting

Shock Hazard

To avoid electrical shock or property damage, disconnect power before installing or servicing equipment. Lowering the control board exposes the technician to 240 VAC electricity inside the fryer.

  1. Turn off unit.

  2. Verify the oil temperature is above melt exit.

    The melt cycle is a continual pulse of heat during startup to slowly heat the oil. If the control displays Melt Cycle, then the burners will pulse heat until reaching the exit temperature. After exiting Melt Cycle, the burner should be on until reaching set point.

  3. If the burners are continually cycling and the oil temperature is above melt, this is a sign of a leak in the blower vacuum path.

  4. Squeeze the orange tube on the vacuum switch while turning on the unit. Assess if the burner is functioning properly.

  5. Ensure the blower is functioning properly.

  6. Ensure the blower tube is not obstructed.

  7. Ensure the baffles are not damaged.

  8. If all parts are functioning properly and undamaged, replace vacuum switch.

Related Content

Replacing the Blower Motor Assembly

Replacing Heating Contactors (Electric Only)

Replacing Heating Elements (Electric Only)

Replacing the High Limit Temperature Control (Electric Units)

Replacing the High Temperature Limit Control (Gas Units)

Replacing the Flame Sensor (Gas Units)

Replacing the Ignitor Module

Replacing the Pilot / Ignitor Assembly

Replacing the Gas Control Valve Assembly

Replacing the Temperature Probe

Replacing the Power Switch

Troubleshooting the OFG 32X Fryer E-4 Control Overheating Error Code

Troubleshooting the OFE and OFG 32X Fryer E-5 Oil Overheating Error Code

Troubleshooting the OFE and OFG 32X Fryer E-6 Temperature Probe Error Code

Troubleshooting the OFE and OFG 32X Fryer E-10 High Limit Error Code

Troubleshooting the OFE and OFG 32X Fryer E-20A Fan Sensor Stuck Closed Error Code

Troubleshooting the OFG 32X Fryer E-20B Pressure Switch Stuck Error Code

Troubleshooting the OFG 32X Fryer E-20D Ignition Failure Error Code

Troubleshooting the OFE 32X Fryer E-26 Heat Amps Locked Error Code

Troubleshooting the OFE and OFG 32X Fryer E-92 24V Circuit Overload Error Code

Troubleshooting the OFE 32X Fryer W-1 Low Voltage Warning

Troubleshooting the OFE 32X Fryer W-2 Slow Heating Warning

Troubleshooting the OFE 32X Fryer W-3 Was Not Ready Warning

Troubleshooting the OFE 32X Fryer W-4 Slow Cooking Warning

Troubleshooting the OFE 32X Fryer W-5 Slow Cooking Warning

Troubleshooting the OFE 32X Fryer W-6 Slow Cooking Warning

Troubleshooting the OFE 32X Fryer W-7 Low Amps Warning

Troubleshooting the OFE 32X Fryer W-9 Discard Product Warning

Reference

Specifications

Error Codes