Applies to:

Error Codes

DISPLAY

CAUSE

PANEL BOARD CORRECTION

“E-4”

Control board overheating

Turn switch to OFF position, then turn switch back to ON; if “E-4” continues, the board is getting too hot; check for signs of overheating behind the control panel; once panel cools down the controls should return to normal; if “E-4” persists, have control panel replaced

“E-5”

Oil overheating

Turn switch to OFF position, then back to ON;

if “E-5” continues, the heating circuits and temperature probe should be checked; once the unit cools down, the controls should return to normal; if “E-5” persists, have control panel replaced

“E-6”

Temperature probe failure

Turn switch to OFF position, then back to ON; if the “E-6” continues, the temperature probe should be checked; once the probe is repaired, or replaced, the controls should return to normal; if “E-6” persists, have control panel replaced

“E-6 A” Temperature probe open Turn switch to OFF position, then turn switch back to ON; if display shows “E-6”, have the temperature probe checked
“E-6 B” Temperature probe shorted Turn switch to OFF position, then turn switch back to ON; if display shows “E-6” have the temperature probe checked

“E-10”

High limit

Allow oil to cool, and then reset the high limit by manually pushing and holding the reset (red rocker) switch for 5 seconds. If the high limit does not reset, the high limit must be replaced.

"E-15" Drain switch failure Close drain, using the drain valve handle; if display still failure shows “E-15”, have the drain microswitch checked
“E-20 A” Vacuum switch failure (stuck closed) Press the timer button to try the ignition process again, and if “E-20 A” persist, check the air switch
“E-20 B” Draft fan or vacuum switch failure (stuck open) Press the timer button to try the ignition process again and if “E-20 B” persist, check the vacuum switch or the blower motor
“E-20 C” Ignition modules not responding Press the timer button to try the ignition process again; if “E-20 C” persists, check the ignition module, the spark ignitor per Pilot/Ignitor Module Section, the I/O board

“E-20 D”

Pilots not lit or no flame sense

Press the timer button to try the ignition process again; if “E-20 D” persists, check the ignition module, the I/O board per Control & I/O Boards Section or the flame sense

“E-25” Heat amps too high Heating elements drawing too much current; have heat circuit checked
“E-26” Heat amps locked on Heating elements are drawing current when controls are not calling for heat; have controls and heat circuit checked
“E-27” Heat amps too low Heating elements current is lower than expected; have heat circuit checked

“E-31”

Elements not hinged all the way down

Check to make sure the elements are hinged all way down into the vat; check for obstructions under elements way down

“E-41” “E-46”

Programming failure

Turn switch to OFF position, then back to ON; if display shows “E-41”, the control should be re- initialized (See Programming Section) if the error code persists, have control panel replaced

“E-47” Analog converter chip or 12 volt supply failure Turn switch to OFF, then back to ON, if “E-47” persists, have the I/O board, or the PC board replaced; if speaker tones are quiet, probably I/O board failure
“E-48” Input system error Have PC board replaced
“E-70 B” Faulty power switch, or switch wiring; faulty I/O board Have power switch checked, along with its wiring; have Input/Output board replaced if necessary
“E-70” Faulty power switch, or switch wiring; faulty I/O board Have power switch checked, along with its wiring; have Input/Output board replaced if necessary

“E-71”

Pump motor relay failure or wiring problem

Replace relay if contacts are stuck closed; check wiring on POWER/PUMP switch, or at wall receptacle; L1 and N may be reversed

“E-92”

24 VAC fuse on I/O board open

Have components, in 24-volt circuit (I.E., hi limit, drain switch) checked for shorts

“E-32, FAN FAIL ERROR, CHECK BLOWER, CLEAN DILUTIONBOX, CALL HENNY PENNY SERVICE” Air pressure switch open; clogged dilution box or faulty blower; open drain switch; open high limit Clean dilution box or replace blower if necessary; have drain switch checked; reset high limit or have high limit checked

CE Only - Along with the previous error codes, CE units have the following self-diagnostic error codes:

DISPLAY

CAUSE

PANEL BOARD CORRECTION

“E-10”

High limit

Allow oil to cool, and then reset the high limit by manually pushing and holding the reset (red rocker) switch for 5 seconds. If the high limit does not reset, the high limit must be replaced.

“E-15”

Drain switch

Close the drain, using the drain valve handle; if display still shows “E-15”, have the drain microswitch checked

“E-20A”

Air pressure switch failure

Press the timer button to try the ignition process again, and if “E-20A” persists, call Henny Penny’s Service (stuck closed) Department

“E-20B” Draft fan or air pressure switch failure (stuck open) Press the timer button to try the ignition process again, and if “E-20B” persists, call Henny Penny’s Service Department

“E-20C”

Left gas module failure

Press the timer button to try the ignition process again, and if “E-20C” persists, call Henny Penny’s Service Department

“E-20D” Right module failure Press the timer button to try the ignition process again, and if “E-20D” persists, call Henny Penny’s Service Department

“E-20E”

Both modules failure

Press the timer button to try the ignition process again, and if “E-20E” persists, call Henny Penny’s Service Department

“E-20F” Left module no flame sense Press the timer button to try the ignition process again, and if “E-20F” persists, call Henny Penny’s Service Department

“E-20G”

Right module no flame sense

Press the timer button to try the ignition process again, and if “E-20G” persists, call Henny Penny’s Service Department

“E-20H” Both modules no flame sense Press the timer button to try the ignition process again, and if “E-20H” persists, call Henny Penny’s Service Department

Related Content

Information about the 590 and 592 Fryers

Installing the 590 and 592 Fryers

Operating the 590 and 592 Fryers

Programming the 590 and 592 Fryers

Troubleshooting the 590 and 592 Fryers

Unpacking

Selecting the Location

Installing the Power Cord

Basic Operation

Changing the Filter Envelope

Filtering

Cleaning the Vat

Maintenance Schedule

Operating Components

Cleaning Deadweight Assembly

Cleaning the Nylatron Slides

Lubricating the Lid Rollers

Reversing the Lid Gasket

Cleaning the Safety Relief Valve

Inspecting the Counterweight Cables

Programming

Special Programming

Replacing the High Temperature Limit Control

Decommissioning Fryers

Replacing the Control Panel

Testing and Replacing the Fuse Holders

PFE 590 and 591 Electronic Control Retrofit Computron 7000 to New Electronic Controls

Retrofit Control Instructions 290-590 KFC to 291-591 GM

Retrofit 292-592 Fast KFC to 291-591 Controls Instructions

FM08-481 8 Head Replacing the Control

FM08-502 8 Head Replacing KFC Control

Troubleshooting the SMS Control Online Projection System (OPS) Connection

Replacing the Heating Elements

Replacing the Contactors

Replacing the Temperature Probe

Electric Power Cord Routing and Attachment Installation Instructions

PFE 592 (FAST Controls) to 590 (Henny Penny Controls) Retrofit Instructions

Testing and Replacing the Power/Pump Switch

Replacing the Drain Microswitch

Replacing the Drain Valve and Extension

Installing the Pump Seal Kit

Direct-Connect Retrofit Instructions (For use on fryers after SN: 290-BE0401001 & 591- LG014JC)

Filter Rinse Hose Retrofit Instructions

Replacing the Nylatron Slides (Cam Slide Filler)

Replacing the Lid Counterweight Cables

Unpacking Instructions

PFE 590 and 591 Installing Optional Crumb Basket

Rear Cover Removal Instructions

Label Application and Location for the 8 Head Fryer

Reference

Specifications

Wiring Diagrams

PFE 590 and 592 Inspection and Planned Maintenance

PFE 590 and 592 KFC Annual Inspection Certification