Error Codes
|
DISPLAY |
CAUSE |
PANEL BOARD CORRECTION |
|---|---|---|
|
“E-4” |
Control board overheating |
Turn switch to OFF position, then turn switch back to ON; if “E-4” continues, the board is getting too hot; check for signs of overheating behind the control panel; once panel cools down the controls should return to normal; if “E-4” persists, have control panel replaced |
|
“E-5” |
Oil overheating |
Turn switch to OFF position, then back to ON; if “E-5” continues, the heating circuits and temperature probe should be checked; once the unit cools down, the controls should return to normal; if “E-5” persists, have control panel replaced |
|
“E-6” |
Temperature probe failure |
Turn switch to OFF position, then back to ON; if the “E-6” continues, the temperature probe should be checked; once the probe is repaired, or replaced, the controls should return to normal; if “E-6” persists, have control panel replaced |
|
“E-41” |
Programming failure |
Turn switch to OFF position, then back to ON; if display shows “E-41”, the control should be re- initialized (See Programming Section) if the error code persists, have control panel replaced |
|
“E-71” |
Pump motor relay failure or wiring problem |
Replace relay if contacts are stuck closed; check wiring on POWER/PUMP switch, or at wall receptacle; L1 and N may be reversed |
CE Only - Along with the previous error codes, CE units have the following self-diagnostic error codes:
|
DISPLAY |
CAUSE |
PANEL BOARD CORRECTION |
|---|---|---|
|
“E-10” |
High limit |
Allow oil to cool, and then reset the high limit. If the high limit does not reset, the high limit must be replaced. To reset the high limit:
|
|
“E-15” |
Drain switch |
Close the drain, using the drain valve handle; if display still shows “E-15”, have the drain microswitch checked |
Related Content
Information about the 590 and 592 Fryers
Installing the 590 and 592 Fryers
Operating the 590 and 592 Fryers
Programming the 590 and 592 Fryers
Training on the 590 and 592 Fryers
Troubleshooting the 590 and 592 Fryers
Cleaning the Safety Relief Valve
Inspecting the Counterweight Cables
Replacing the High Temperature Limit Control
Testing and Replacing the Fuse Holders
PFE 590 and 591 Electronic Control Retrofit Computron 7000 to New Electronic Controls
Retrofit Control Instructions 290-590 KFC to 291-591 GM
Retrofit 292-592 Fast KFC to 291-591 Controls Instructions
FM08-481 8 Head Replacing the Control
FM08-502 8 Head Replacing KFC Control
Troubleshooting the SMS Control Online Projection System (OPS) Connection
Troubleshooting the C8000 Open Fryer Message
Troubleshooting the PFE 590 and 592 E-41 Control Programming Lost Error Code
Replacing the Heating Elements
Replacing the Temperature Probe
Electric Power Cord Routing and Attachment Installation Instructions
PFE 592 (FAST Controls) to 590 (Henny Penny Controls) Retrofit Instructions
Troubleshooting the PFE 590 and 592 E-6 Temperature Probe Error Code
Troubleshooting the PFE 590 and 592 E-10 High Limit Error Code
Troubleshooting the PFE 590 and 592 No Heat Error Code
Testing and Replacing the Power/Pump Switch
Replacing the Drain Microswitch
Replacing the Drain Valve and Extension
Direct-Connect Retrofit Instructions (For use on fryers after SN: 290-BE0401001 & 591- LG014JC)
Filter Rinse Hose Retrofit Instructions
Troubleshooting the PFE 590 and 592 Not Pumping Error Code
Replacing the Nylatron Slides (Cam Slide Filler)
Replacing the Lid Counterweight Cables
PFE 590 and 591 Installing Optional Crumb Basket
Rear Cover Removal Instructions
Label Application and Location for the 8 Head Fryer
Reference
PFE 590 and 592 Inspection and Planned Maintenance