Applies to:
ALL CUSTOMERS
Electric Power Cord Routing and Attachment Installation Instructions
Estimated Time
30 Minutes
Installation instructions for electric 8 head power cord routing and attachment.
-
Remove power from unit.
-
Remove control panel.
-
Remove drain rod access cover.
-
Route power cord under frame in front of rear caster through power cord clamp.
-
Pull cord through clamp on rear of insulation box and through electrical fitting on contactor bracket assembly.
-
With approximately 1/2 in. of cord insulation through clamp, tighten clamp around cord securely.
-
Pull all wires through contactor bracket and route up into the control area.
-
Attach all wires to wiring diagram.
-
Put side panel, drain rod access cover and control panel back in place.
-
Plug fryer in.
-
Fryer is now ready for use.
-
Remove right side panel.
Related Content
Replacing the Heating Elements
Replacing the Temperature Probe
PFE 592 (FAST Controls) to 590 (Henny Penny Controls) Retrofit Instructions
PFE 590 and 591 Electronic Control Retrofit Computron 7000 to New Electronic Controls
Direct-Connect Retrofit Instructions (For use on fryers after SN: 290-BE0401001 & 591- LG014JC)
Retrofit Control Instructions 290-590 KFC to 291-591 GM
Retrofit 292-592 Fast KFC to 291-591 Controls Instructions
PFE 590 and 591 Installing Optional Crumb Basket
Filter Rinse Hose Retrofit Instructions
Rear Cover Removal Instructions
Label Application and Location for the 8 Head Fryer
FM08-481 8 Head Replacing the Control
FM08-502 8 Head Replacing KFC Control
Replacing the High Temperature Limit Control
Replacing the Temperature Probe
Replacing the Heating Elements
Reference
PFE 590 and 592 Inspection and Planned Maintenance