SCR Wireway Tall Instructions

Kit number

14309

Estimated Time

1 Hour

  1. Disconnect power cord from power source.

  2. Remove access panels from top and bottom rotisseries.

  3. If casters are installed lock casters before drilling holes proceed to next step.

    1. Drill holes in top rotisserie.

    2. Drill holes in bottom rotisserie.

  4. Loosen both strain relief and disconnect power cord from top and bottom rotisserie. Before disconnecting cord, make note of how wires are connected.

  5. Carefully cut away 4 inches of out black insulation from each power cord.

  6. Remove strain relief from cord bracket on top rotisserie.

  7. Attach the same strain relief to drilled hole (1-3/8).

  8. Insert power cord through strain relief and reconnect power cord. Repeat for bottom rotisserie.

  9. Unit is now ready for power cord cover.

  10. Use screws that are provided attach wireway base to top and bottom rotisseries.

  11. For proper fit align oval holes on wireway base with drilled holed (.136) on rotisseries.

  12. Place power cord along wireway base and attach wireway cover using screws that are provided.

  13. On top rotisserie remove hex nuts from cord bracket and position bracket. Hole should now be directed downward.

  14. Fasten bracket again using the same hex nuts (repeat for bottom rotisserie) and then re-install both access panels.

  15. Wireway cover installation is now complete.