Applies to:
Troubleshooting the SMS Control Online Projection System (OPS) Connection
For the KFC in-store OPS system and SMS 20 control to properly communicate the Zigbee radio system must be enabled. Instructions for enabling the Zigbee radio system are below:
Press and hold the FUNCTION button for two (2) seconds.
Release the FUNCTION button when REGULAR PROGRAMMING shows in the display.
Repeatedly press and release FUNCTION button to scroll to FACTORY PRESETS.
Enter access code 2957.
Repeatedly press and release FUNCTION button to scroll to ZIGBEE ENABLE.
Press and release product button 1 to toggle ZIGBEE ENABLE ON or OFF.
Press and hold FUNCTION button to exit programming.
To check for Zigbee radio connection:
With fryer power switch OFF, press and hold product buttons 8 and 9 simultaneously.
The ZIGBEE INFO screen displays if the radio is connected to the network or not.
If the Zigbee radio is disconnected from the network, it can be connected by pressing product button 10. From the ZIGBEE INFO screen, radio channel and ID display.
Related Content
Replacing the Indicator Lights
Replacing the Main Power Switch
Electronic C2000 Simple Control Retrofit Kit
Installation of PFG 600 and PFG 600 SSI FM07-366 Electromechanical to C1000 Retrofit
PFG 600 SSI Electronic C1000 to C8000 Retrofit Kit
RLink programming instructions
PFE 500/PFG 600 Wi-Fi Verification and Troubleshooting Instructions
PFE 500/PFG 600 Hybrid Control Installation Instructions
FAST Control Installation Instructions
2nd Generation Radio for SMS: Hardware Installation
2nd Generation Radio for SMS: Software Update
FM08-748 2nd Generation Radio for SMS: Troubleshooting
Instructions for Fryer Control Replacement Kits
SMS 20 Auto Polish Programming Instructions
Hybrid Control and Wi-Fi Installation
Troubleshooting the SMS 20 Control Countdown
Reference