Applies to:

Replacing the Air Valve

The air valve allows circulation of the shortening in the frypot to keep the shortening at a uniform temperature.

To avoid electrical shock or property damage, move the power switch to OFF and disconnect power.

NOTICE -

To avoid property damage, do not tamper with this component. It is factory sealed and should not be adjusted.

  1. Remove the electrical power supplied to the unit.

  2. Remove the left side panel.

  3. Remove the wires from the wire nuts.

  4. Disconnect union at the valve.

  5. Loosen the nut on the conduit connector and pull coil from conduit.

  6. Remove close nipple and female part of union from valve body.

  7. Replace with new valve in reverse order.

Related Content

Replacing the High Temperature Limit Control

Replacing the Temperature Probe

Replacing the Transformer

Replacing the Gas Control Valve

Replacing the Airflow Switch

Replacing the Flame Sensor Assembly

Replacing the Ignitor Assembly

Replacing the Ignition Modules

Replacing the Blower Assembly

8 Head Baso Retrofit Kit

PFG-69X & OFG-39X Gas Valve Replacement Kit

Repositioning/Rewiring Air Valves for 220240V Model 690/390 fryers

Repositioning / Rewiring Air Valves for 120V Model 690/390 fryers

FM07-558 Gas Valve Replacement Kit

Ignition Module Retrofit Kits

Manifold Retrofit Kit Instructions

PFG 690/691 Ignition Module Kit

Mounting the OFG 390 and PFG 690 Vacuum Switch

PFG 690 and 691 Temperature Probe CE Instructions

Replace Gas Valve Assembly with Gas Valve and Solenoid Assembly

Replacing Gas Valve Assembly With Gas Valve and Solenoid Assembly

Air Switch Monitoring Retrofit Kit Instructions

CE Gas Valve Adjustment Instructions

Troubleshooting the PFG 690 and 692 E-4 Control Overheating Error Code

Troubleshooting the PFG 690 and 692 E-5 Oil Overheating Error Code

Troubleshooting the PFG 690 and 692 E-6 Temperature Probe Error Code

Troubleshooting the PFG 690 and 692 E-10 High Limit Error Code

Troubleshooting the PFG 690 and 692 E-32 High Limit, Drain Valve, Vacuum Switch and Blower Motor Error Code

Reference

PFG 690 and 692 Inspection and Planned Maintenance

Error Codes

PFG 690 Wiring Diagrams

Specifications

PFG 690 and 692 KFC Annual Inspection Certification

1000 Ohm Chart

Fastron RTD Chart