Applies to:
The air valve allows circulation of the shortening in the frypot to keep the shortening at a uniform temperature.
![]() |
To avoid electrical shock or property damage, move the power switch to OFF and disconnect power. |
NOTICE - |
To avoid property damage, do not tamper with this component. It is factory sealed and should not be adjusted. |
-
Remove the electrical power supplied to the unit.
-
Remove the left side panel.
-
Remove the wires from the wire nuts.
-
Disconnect union at the valve.
-
Loosen the nut on the conduit connector and pull coil from conduit.
-
Remove close nipple and female part of union from valve body.
-
Replace with new valve in reverse order.