Error Codes
DISPLAY |
CAUSE |
PANEL BOARD CORRECTION |
---|---|---|
“E-4” |
Control board overheating |
Turn switch to OFF position, then turn switch back to ON; if “E-4” continues, the board is getting too hot; check for signs of overheating behind the control panel; once panel cools down the controls should return to normal; if “E-4” persists, have control panel replaced |
“E-5” |
Oil overheating |
Turn switch to OFF position, then back to ON; if “E-5” continues, the heating circuits and temperature probe should be checked; once the unit cools down, the controls should return to normal; if “E-5” persists, have control panel replaced |
“E-6” |
Temperature probe failure |
Turn switch to OFF position, then back to ON; if the “E-6” continues, the temperature probe should be checked; once the probe is repaired, or replaced, the controls should return to normal; if “E-6” persists, have control panel replaced |
“E-41” |
Programming failure |
Turn switch to OFF position, then back to ON; if display shows “E-41”, the control should be re- initialized (See Programming Section) if the error code persists, have control panel replaced |
“E-71” |
Pump motor relay failure or wiring problem |
Replace relay if contacts are stuck closed; check wiring on POWER/PUMP switch, or at wall receptacle; L1 and N may be reversed |
“E-32, FAN FAIL ERROR, CHECK BLOWER, CLEAN DILUTIONBOX, CALL HENNY PENNY SERVICE” | Air pressure switch open; clogged dilution box or faulty blower; open drain switch; open high limit | Clean dilution box or replace blower if necessary; have drain switch checked; reset high limit or have high limit checked |
CE Only - Along with the previous error codes, CE units have the following self-diagnostic error codes:
DISPLAY |
CAUSE |
PANEL BOARD CORRECTION |
---|---|---|
“E-10” |
High limit |
Allow oil to cool, and then reset the high limit by manually pushing and holding the reset (red rocker) switch for 5 seconds. If the high limit does not reset, the high limit must be replaced. |
“E-15” |
Drain switch |
Close the drain, using the drain valve handle; if display still shows “E-15”, have the drain microswitch checked |
“E-20A” |
Air pressure switch failure |
Press the timer button to try the ignition process again, and if “E-20A” persists, call Henny Penny’s Service (stuck closed) Department |
“E-20B” | Draft fan or air pressure switch failure (stuck open) | Press the timer button to try the ignition process again, and if “E-20B” persists, call Henny Penny’s Service Department |
“E-20C” |
Left gas module failure |
Press the timer button to try the ignition process again, and if “E-20C” persists, call Henny Penny’s Service Department |
“E-20D” | Right module failure | Press the timer button to try the ignition process again, and if “E-20D” persists, call Henny Penny’s Service Department |
“E-20E” |
Both modules failure |
Press the timer button to try the ignition process again, and if “E-20E” persists, call Henny Penny’s Service Department |
“E-20F” | Left module no flame sense | Press the timer button to try the ignition process again, and if “E-20F” persists, call Henny Penny’s Service Department |
“E-20G” |
Right module no flame sense |
Press the timer button to try the ignition process again, and if “E-20G” persists, call Henny Penny’s Service Department |
“E-20H” | Both modules no flame sense | Press the timer button to try the ignition process again, and if “E-20H” persists, call Henny Penny’s Service Department |
Related Content
Information about the 690 and 692 Fryers
Installing the 690 and 692 Fryers
Operating the 690 and 692 Fryers
Programming the 690 and 692 Fryers
Troubleshooting the 690 and 692 Fryers
Cleaning the Safety Relief Valve
FM08-502 8 Head Replacing KFC Control
FM08-481 8 Head Replacing the Control
Conversion From C8000 Control to KFC SMS Control
Conversion From Standard 690 Control to S/M Control
PFG 691 C8000 Retrofit Instructions
Troubleshooting the SMS Control Online Projection System (OPS) Connection
Replacing the High Temperature Limit Control
Replacing the Temperature Probe
Replacing the Gas Control Valve
Replacing the Flame Sensor Assembly
Replacing the Ignitor Assembly
Replacing the Ignition Modules
PFG-69X & OFG-39X Gas Valve Replacement Kit
Repositioning/Rewiring Air Valves for 220240V Model 690/390 fryers
Repositioning / Rewiring Air Valves for 120V Model 690/390 fryers
FM07-558 Gas Valve Replacement Kit
Manifold Retrofit Kit Instructions
PFG 690/691 Ignition Module Kit
Mounting the OFG 390 and PFG 690 Vacuum Switch
PFG 690 and 691 Temperature Probe CE Instructions
Replace Gas Valve Assembly with Gas Valve and Solenoid Assembly
Replacing Gas Valve Assembly With Gas Valve and Solenoid Assembly
Air Switch Monitoring Retrofit Kit Instructions
CE Gas Valve Adjustment Instructions
Testing and Replacing the Power/Pump Switch
Replacing the Drain Microswitch
Replacing the Drain Valve and Extension
PFG-690/691 & OFG-390/391 Pump Motor Relay Kit
PFG 690 and 691 Installing Filter Rinse Hose
Operating Instructions for PFG-691/OFG-391 Direct-Connect Oil System
Direct-Connect Retrofit Instructions (For use on fryers after SN: 391-LH016JC & 691-LH029JC)
Replacing the Lid Counterweight Cables
Calibrating and Cleaning the Pressure Gauge
I-Beam Cable Hole Plug Installation
Replace Nylatron Slides on PFG 690 and 691
PFG 690 and 691 Lid Cable Replacement
Label Application and Location for the 8 Head Fryer
Rear Cover Removal Instructions
Installing Optional Crumb Basket
PFG 690 Stabilizer Retrofit Instructions
Reference