Applies to:
The transformer reduces the voltage down to accommodate those components with low voltage.
To avoid electrical shock or property damage, move the power switch to OFF and disconnect power. |
-
Remove the electrical power supplied to the unit.
-
Remove the control panel.
-
Remove the two (2) screws securing the transformer to the unit and remove transformer.
Mark wires before removal to insure new transformer is wired correctly.
-
Remove the wires from transformer.
-
Replace with new transformer and install in reverse order.