Applies to:
ALL CUSTOMERS
PFG 690 and 691 Temperature Probe CE Instructions
![Closed](../../../Skins/Default/Stylesheets/Images/transparent.gif)
Crosstip head screwdriver
Flat-head screwdriver
Wire cutters
Kit number
14266
Estimated Time
30 Minutes
![]() |
To avoid electrical shock or property damage, move the power switch to OFF and disconnect power. |
This kit is for making modifications to 690 CE units with the temperature probe connected directly to the 15 pin connector. This kit will create an intermediate connection for easier separation and replacement of the temperature probe
-
Disconnect power from the 690 unit.
-
Cut the (2) wires on the temp. probe 3 to 4” from the 15 pin connector.
-
Strip the newly exposed ends 1/8”.
-
Crimp (2) EC01-023 terminals on the ends of the wires still attached to the 15 pin terminal.
-
Insert these terminal ends into the EC01-028 connector provided in positions 3 and 4.
-
Crimp (2) EC01-020 terminals on the ends of the wires still attached to the temp. probe.
-
Insert these terminal ends into the remaining EC01-027 connector in positions 3 and 4.
-
Connect EC01-028 and EC01-027.
-
Return power to unit
Related Content
Replacing the High Temperature Limit Control
Replacing the Temperature Probe
Replacing the Gas Control Valve
Replacing the Flame Sensor Assembly
Replacing the Ignitor Assembly
Replacing the Ignition Modules
PFG-69X & OFG-39X Gas Valve Replacement Kit
Repositioning/Rewiring Air Valves for 220240V Model 690/390 fryers
Repositioning / Rewiring Air Valves for 120V Model 690/390 fryers
FM07-558 Gas Valve Replacement Kit
Manifold Retrofit Kit Instructions
PFG 690/691 Ignition Module Kit
Mounting the OFG 390 and PFG 690 Vacuum Switch
Replace Gas Valve Assembly with Gas Valve and Solenoid Assembly
Replacing Gas Valve Assembly With Gas Valve and Solenoid Assembly
Air Switch Monitoring Retrofit Kit Instructions
CE Gas Valve Adjustment Instructions
I-Beam Cable Hole Plug Installation
FM08-502 8 Head Replacing KFC Control
FM08-481 8 Head Replacing the Control
Label Application and Location for the 8 Head Fryer
PFG-690/691 & OFG-390/391 Pump Motor Relay Kit
Conversion From C8000 Control to KFC SMS Control
Rear Cover Removal Instructions
Replace Nylatron Slides on PFG 690 and 691
Installing Optional Crumb Basket
PFG 690 and 691 Installing Filter Rinse Hose
PFG 690 Stabilizer Retrofit Instructions
Conversion From Standard 690 Control to S/M Control
PFG 691 C8000 Retrofit Instructions
PFG 690 and 691 Lid Cable Replacement
Operating Instructions for PFG-691/OFG-391 Direct-Connect Oil System
Direct-Connect Retrofit Instructions (For use on fryers after SN: 391-LH016JC & 691-LH029JC)
Replacing the High Temperature Limit Control
Replacing the Temperature Probe
Replacing the Gas Control Valve
Replacing the Flame Sensor Assembly
Replacing the Ignition Modules
Replacing the Ignitor Assembly
PFG 691 Attaching the Rinse Hose Instructions
Reference
PFG 690 and 692 Inspection and Planned Maintenance