Applies to:

ALL CUSTOMERS

PFG 690 and 691 Temperature Probe CE Instructions

Kit number

14266

Estimated Time

30 Minutes

To avoid electrical shock or property damage, move the power switch to OFF and disconnect power.

This kit is for making modifications to 690 CE units with the temperature probe connected directly to the 15 pin connector. This kit will create an intermediate connection for easier separation and replacement of the temperature probe

  1. Disconnect power from the 690 unit.

  2. Cut the (2) wires on the temp. probe 3 to 4” from the 15 pin connector.

  3. Strip the newly exposed ends 1/8”.

  4. Crimp (2) EC01-023 terminals on the ends of the wires still attached to the 15 pin terminal.

  5. Insert these terminal ends into the EC01-028 connector provided in positions 3 and 4.

  6. Crimp (2) EC01-020 terminals on the ends of the wires still attached to the temp. probe.

  7. Insert these terminal ends into the remaining EC01-027 connector in positions 3 and 4.

  8. Connect EC01-028 and EC01-027.

  9. Return power to unit

Related Content

Replacing the High Temperature Limit Control

Replacing the Temperature Probe

Replacing the Transformer

Replacing the Gas Control Valve

Replacing the Airflow Switch

Replacing the Air Valve

Replacing the Flame Sensor Assembly

Replacing the Ignitor Assembly

Replacing the Ignition Modules

Replacing the Blower Assembly

8 Head Baso Retrofit Kit

PFG-69X & OFG-39X Gas Valve Replacement Kit

Repositioning/Rewiring Air Valves for 220240V Model 690/390 fryers

Repositioning / Rewiring Air Valves for 120V Model 690/390 fryers

FM07-558 Gas Valve Replacement Kit

Ignition Module Retrofit Kits

Manifold Retrofit Kit Instructions

PFG 690/691 Ignition Module Kit

Mounting the OFG 390 and PFG 690 Vacuum Switch

Replace Gas Valve Assembly with Gas Valve and Solenoid Assembly

Replacing Gas Valve Assembly With Gas Valve and Solenoid Assembly

Air Switch Monitoring Retrofit Kit Instructions

CE Gas Valve Adjustment Instructions

I-Beam Cable Hole Plug Installation

FM08-502 8 Head Replacing KFC Control

FM08-481 8 Head Replacing the Control

Label Application and Location for the 8 Head Fryer

PFG-690/691 & OFG-390/391 Pump Motor Relay Kit

Pan Spacer Bracket

PFG 690 to 692 Retrofit Kit

Conversion From C8000 Control to KFC SMS Control

Rear Cover Removal Instructions

Replace Nylatron Slides on PFG 690 and 691

Installing Optional Crumb Basket

PFG 690 and 691 Installing Filter Rinse Hose

Installing the Pump Seal Kit

Unpacking Instructions

PFG 690 Stabilizer Retrofit Instructions

Conversion From Standard 690 Control to S/M Control

PFG 691 C8000 Retrofit Instructions

PFG 690 and 691 Lid Cable Replacement

Operating Instructions for PFG-691/OFG-391 Direct-Connect Oil System

Direct-Connect Retrofit Instructions (For use on fryers after SN: 391-LH016JC & 691-LH029JC)

Replacing the High Temperature Limit Control

Replacing the Temperature Probe

Replacing the Transformer

Replacing the Gas Control Valve

Replacing the Flame Sensor Assembly

Replacing the Air Valve

Replacing the Airflow Switch

Replacing the Ignition Modules

Replacing the Ignitor Assembly

Replacing the Blower Assembly

PFG 691 Attaching the Rinse Hose Instructions

Reference

PFG 690 and 692 Inspection and Planned Maintenance

Error Codes

PFG 690 Wiring Diagrams

Specifications

PFG 690 and 692 KFC Annual Inspection Certification

Specifications

Error Codes

PFG 691 Wiring Diagrams

PFG 691 Inspection and Planned Maintenance