Applies to:

Replacing the Temperature Probe

The temperature probe relays the actual oil temperature to the control. If it becomes disabled, “E06” will show in the display. Also, if the temperature is out of calibration more than 10°F, or 10°C, the temperature probe should be replaced. An Ohm check also can be performed.

To avoid electrical shock or property damage, move the power switch to OFF and disconnect power.

  1. Remove electrical power supplied to the fryer.

  2. Drain the oil from the vat.

  3. Remove the control panel.

  4. Using a 1/2 inch wrench, remove the nut on the compression fitting.

  5. Remove the temperature probe from the vat.

  6. Place the nut and new ferrule on the new temperature probe and insert the temperature probe into the compression fitting until it extends one-half (1/2) inch (1.3 cm) into the vat.

  7. Use the temperature probe gauge provided in the temperature probe kit, to ensure proper placement in vat.

    Excess force will damage the temperature probe.

  8. Tighten hand tight and then a half turn with wrench.

  9. Connect new temperature probe to PC board and replace control panel.

  10. Replace oil in vats.

  11. Turn power on and test fryer.

Related Content

Replacing the High Temperature Limit Control

Replacing the Transformer

Replacing the Gas Control Valve

Replacing the Airflow Switch

Replacing the Air Valve

Replacing the Flame Sensor Assembly

Replacing the Ignitor Assembly

Replacing the Ignition Modules

Replacing the Blower Assembly

8 Head Baso Retrofit Kit

PFG-69X & OFG-39X Gas Valve Replacement Kit

Repositioning/Rewiring Air Valves for 220240V Model 690/390 fryers

Repositioning / Rewiring Air Valves for 120V Model 690/390 fryers

FM07-558 Gas Valve Replacement Kit

Ignition Module Retrofit Kits

Manifold Retrofit Kit Instructions

PFG 690/691 Ignition Module Kit

Mounting the OFG 390 and PFG 690 Vacuum Switch

PFG 690 and 691 Temperature Probe CE Instructions

Replace Gas Valve Assembly with Gas Valve and Solenoid Assembly

Replacing Gas Valve Assembly With Gas Valve and Solenoid Assembly

Air Switch Monitoring Retrofit Kit Instructions

CE Gas Valve Adjustment Instructions

Troubleshooting the PFG 690 and 692 E-4 Control Overheating Error Code

Troubleshooting the PFG 690 and 692 E-5 Oil Overheating Error Code

Troubleshooting the PFG 690 and 692 E-6 Temperature Probe Error Code

Troubleshooting the PFG 690 and 692 E-10 High Limit Error Code

Troubleshooting the PFG 690 and 692 E-32 High Limit, Drain Valve, Vacuum Switch and Blower Motor Error Code

Reference

PFG 690 and 692 Inspection and Planned Maintenance

Error Codes

PFG 690 Wiring Diagrams

Specifications

PFG 690 and 692 KFC Annual Inspection Certification

1000 Ohm Chart

Fastron RTD Chart