Applies to:

ALL CUSTOMERS

PFG 691 Attaching the Rinse Hose Instructions

Kit number

14259

Estimated Time

30 Minutes

To avoid severe burns when using filter rinse, turn main power switch to off and use PPE.

Only connect and disconnect the filter rinse hose when the main power switch is in the off position.

To avoid severe burns, use PPE when using filter rinse hose.

The filter rinse hose and fitting will be hot. Use protective gloves or cloth when following this procedure or severe burns could result.

Only perform this procedure when the unit is cool or severe burns may result.

Burn Risk

Using PPE, remove hot oil from fryer before performing procedure or personal injury may occur.

Note: All new pipe joints must include pipe sealant.

  1. Remove the ‘U’ shaped tube from the existing assembly and discard.

  2. Remove the reducer assembly that screws to the check valve. This includes a 3/8” close nipple, a black iron reducer, and a compression fitting body. Attempt to keep the check valve on the vat. This may not be possible, but if the check valve is removed, whatever is in the pot will leak on the floor.

  3. Screw the 4” long black iron pipe nipple assembly (#56979) into the check valve.

  4. Assemble the filter valve to the black iron elbow at the front of the previous assembly. Note: The end with the separate hex fitting should be at the top.

  5. Assemble the tee assembly to the filter valve using the new 3/8 in. close nipple

  6. Attach the tubing assembly. It should run from the pump to the tee assembly. In order to gain clearance, it may be necessary to loosen the pump motor where it mounts to the fryer frame. DO NOT remove the pump motor, simply loosen the bolts to allow you to move the pump motor assembly for proper alignment.

  7. Ensure the pump motor is again securely mounted.

Related Content

Replacing the Drain Microswitch

Replacing the Drain Valve and Extension

Testing and Replacing the Power/Pump Switch

Replacing the Solenoid Below the Counter

Replacing the Solenoid Above the Counter

Installing the Pump Seal Kit

PFG-690/691 & OFG-390/391 Pump Motor Relay Kit

Pan Spacer Bracket

PFG 690 and 691 Installing Filter Rinse Hose

Direct-Connect Retrofit Instructions (For use on fryers after SN: 391-LH016JC & 691-LH029JC)

Operating Instructions for PFG-691/OFG-391 Direct-Connect Oil System

Troubleshooting the PFG 691 Oil Not Pumping

Troubleshooting the PFG 691 E-15 Drain Open Error Code

I-Beam Cable Hole Plug Installation

FM08-481 8 Head Replacing the Control

Label Application and Location for the 8 Head Fryer

8 Head Baso Retrofit Kit

FM07-558 Gas Valve Replacement Kit

Ignition Module Retrofit Kits

Manifold Retrofit Kit Instructions

Replace Nylatron Slides on PFG 690 and 691

Installing Optional Crumb Basket

CE Gas Valve Adjustment Instructions

PFG 691 C8000 Retrofit Instructions

PFG 690 and 691 Lid Cable Replacement

Air Switch Monitoring Retrofit Kit Instructions

Replacing Gas Valve Assembly With Gas Valve and Solenoid Assembly

Replace Gas Valve Assembly with Gas Valve and Solenoid Assembly

PFG 690 and 691 Temperature Probe CE Instructions

PFG 690/691 Ignition Module Kit

PFG 690 Stabilizer Retrofit Instructions

Unpacking Instructions

Replacing High Limit Thermocouple

Reference

Specifications

Error Codes

PFG 691 Wiring Diagrams

PFG 691 Inspection and Planned Maintenance

1000 Ohm Chart

Replacing High Limit Thermocouple