Applies to:
ALL CUSTOMERS
Direct-Connect Retrofit Instructions (For use on fryers after SN: 391-LH016JC & 691-LH029JC)

Adjustable wrench or 1-1/2 in. wrench
Crosstip head screwdriver
Electric drill with crosstip bit
Tape measure
Pipe sealant
Kit number
14639
Estimated Time
1 Hour
-
Use a crosstip head screwdriver to remove left side panel and rear panel from fryer.
-
Use an adjustable, or 1-1/2” wrench to loosen the two fittings to the pump return line and pull the short tube assembly from fryer.
-
Loosen the filter motor mounting bolts, if necessary.
-
Unscrew the check valve assembly from the elbow.
-
Unscrew the elbow from the vat.
-
Locate the elbow and nipple assembly in the kit. Place pipe sealant on the threads of the nipple and screw into the vat and tighten.
-
Locate the check valve and diverter assembly in the kit. Place pipe sealant onto threads of nipple and screw the parts onto the elbow, coming from the vat, and tighten.
-
Locate male connector in kit. Place pipe sealant onto threads and screw it into the diverter valve and tighten.
-
Locate the pump-check valve tube assembly in the kit and install it between the pump elbow and the male connector. Tighten all fittings with a wrench.
-
If the filter pump motor mounting bolts are loose, they must be tightened at this time. Lift up on the motor when tightening the bolts, or the motor will interfere with the filter pan.
-
Locate the handle and the “DISCARD OIL” label in kit. Place the label on the top, front edge of the handle. Remove nut on front of diverter valve, place handle over threaded shaft, and secure the handle with the nut and tighten.
-
Locate the direct-connect tube assembly in kit and fasten the fitting onto the elbow on the end of the check valve and diverter assembly.
-
Using the self-drilling screws supplied in the kit, mount the direct-connect tube assembly bracket to the rear frame.
-
Locate the Direct Connect hose assembly in the kit. Fasten the elbow onto the direct-connect tube assembly and tighten.
NOTE: The check valve and elbow should already be assembled in the kit.
-
Install two elbows on the solenoid valve. Make sure the opening of elbow is facing the back of the unit.
-
Reinstall the side and rear panels, and fryer is now ready for use.
Related Content
Testing and Replacing the Power/Pump Switch
Replacing the Drain Microswitch
Replacing the Drain Valve and Extension
PFG-690/691 & OFG-390/391 Pump Motor Relay Kit
PFG 690 and 691 Installing Filter Rinse Hose
Operating Instructions for PFG-691/OFG-391 Direct-Connect Oil System
I-Beam Cable Hole Plug Installation
FM08-502 8 Head Replacing KFC Control
FM08-481 8 Head Replacing the Control
Label Application and Location for the 8 Head Fryer
PFG-69X & OFG-39X Gas Valve Replacement Kit
Repositioning/Rewiring Air Valves for 220240V Model 690/390 fryers
Repositioning / Rewiring Air Valves for 120V Model 690/390 fryers
FM07-558 Gas Valve Replacement Kit
Conversion From C8000 Control to KFC SMS Control
Rear Cover Removal Instructions
Manifold Retrofit Kit Instructions
Replace Nylatron Slides on PFG 690 and 691
Installing Optional Crumb Basket
PFG 690 Stabilizer Retrofit Instructions
PFG 690/691 Ignition Module Kit
Mounting the OFG 390 and PFG 690 Vacuum Switch
Conversion From Standard 690 Control to S/M Control
PFG 690 and 691 Temperature Probe CE Instructions
Replace Gas Valve Assembly with Gas Valve and Solenoid Assembly
Replacing Gas Valve Assembly With Gas Valve and Solenoid Assembly
Air Switch Monitoring Retrofit Kit Instructions
PFG 691 C8000 Retrofit Instructions
PFG 690 and 691 Lid Cable Replacement
CE Gas Valve Adjustment Instructions
Replacing the Drain Microswitch
Replacing the Drain Valve and Extension
Testing and Replacing the Power/Pump Switch
Replacing the Solenoid Below the Counter
Replacing the Solenoid Above the Counter
PFG 691 Attaching the Rinse Hose Instructions
Reference
PFG 690 and 692 Inspection and Planned Maintenance