Applies to:

Add pressure gauge to PXE unit Instructions (Japan / Hong Kong)

Estimated Time

30 Minutes

  1. Ensure the proper materials are ready to do the procedure.

  2. Remove assembly of 1/4 in. siphon tube, ball valve, and pressure gauge from material packaging.

  3. Use a 1/4 in. hex drive to remove 1/4 in. NPT hex plug from coupling inside of rear shroud top cover.

  4. Apply pipe thread sealant on exposed pipe threads of siphon tube.

  5. Insert into rear shroud top cover and align to coupling.

  6. Tighten into coupling until a tight seal. Ensure gauge is facing toward front of unit and valve opens towards the front of unit.

Related Content

Replacing the Cam Guide

Replacing the Lid Cable

Replacing the Nylatron Vertical Strip

Armored Cable Grounding Installation Instructions for Australia

Lid Latch Adjustment or Replacement

Velocity Steam Box Swap-out Instructions

Velocity Nylatron Vertical Filler Strips Installation Instructions

Lid Handle Replacement Instructions

Securing Latch Pin Block

Lid Latch Replacement

Velocity Deadweight Orifice Clean-out Tool Installation and Maintenance

Velocity Lid Cable Replacement

Instructions to replace PXE Interlock Latch Pivot Pin

Add pressure gauge to PXE unit Instructions

Installing the Pump Seal Kit

ZigBee Radio Communication Kit

Replacing the Filter Valve

Save PXE 100 Setpoints

Selector Valve Motor/Encoder Replacement

Front Dispose Addition (for Bulk Oil Units)

Remove Selector Valve to ATO flex tube

Temp/Level Probe Fitting Replacement

Label Replacement Instructions

High Limit Protection Probe Installation (CE Version built prior to 5/2020, ALL Versions after)

High Limit Protection Probe Installation (UL Version built prior to 5/2020)

Menu Card Removal Replacement Instructions

Re-flashing Instructions

Save and Load Setpoint Instructions

PXE Pump Motor Installation

Flexible Line Replacement Kit (Formed Tube), (Standard, Bulk-Oil Fryer)

Flexible Line Replacement Kit (Formed Tube), (Standard, NON Bulk-Oil Fryer)

JIB Pump Retrofit

Velocity High Limit Adjustment Instructions

Reference

Specifications

Menu Structure

Heating Times

Product Racking Recommendations

Error Codes

PXE 100 Plumbing Diagrams

PXE 100 Wiring Diagrams

PXE 100 Inspection and Planned Maintenance

PXE 100 KFC Annual Inspection Certification