Applies to:

Lid Latch Replacement

Kit number

92484

Estimated Time

60 Minutes

To avoid electrical shock or property damage, move the power switch to OFF and disconnect power.

Only perform this procedure when the unit is cool or severe burns may result.

This procedure should only be performed by an experienced welder. Otherwise, injury or property damage may occur

Procedure

To replace a broken lid latch on Velocity fryers

  1. Disconnect power from fryer.

  2. Use an angle grinder to grind off the remains of the existing catch clip.

  3. Use a degreasing agent to clean the front of the vat band.

  4. Use a marker to mark the horizontal location of the new catch clip. Clip should be centered with 6.945 +/- 0.060 in. on either side.

  5. Use a marker to mark the vertical location of the new catch clip. Bottom of the clip should be 1.345 +/- 0.020 inches from top of countertop.

  6. Use gas tungsten arc welding (GTAW) and a 316L filler to attch the new clip.

  7. Use a wire brush to remove heat discoloration.

  8. Use an adjustable wrench to adjust lid latch.

  9. Gently flex the latch in or out as required.

  10. Use an adjustable wrench to adjust the lid catch.

  11. Gently flex the catch in or out as required.

  12. Open and close the lid while inspecting the lid latch and catch for engagement.

The lid latch to catch engagement should be smooth and not clunky. The lid latch should gently but firmly slide over the catch and engage without excessive play. If the lid must be slammed to lock, the engagement is too tight. If clip is not adjusted properly, damage to the clip may occur.

Related Content

Replacing the Cam Guide

Replacing the Lid Cable

Replacing the Nylatron Vertical Strip

Armored Cable Grounding Installation Instructions for Australia

Lid Latch Adjustment or Replacement

Velocity Steam Box Swap-out Instructions

Velocity Nylatron Vertical Filler Strips Installation Instructions

Lid Handle Replacement Instructions

Securing Latch Pin Block

Velocity Deadweight Orifice Clean-out Tool Installation and Maintenance

Velocity Lid Cable Replacement

Add pressure gauge to PXE unit Instructions (Japan / Hong Kong)

Instructions to replace PXE Interlock Latch Pivot Pin

Add pressure gauge to PXE unit Instructions

Installing the Pump Seal Kit

ZigBee Radio Communication Kit

Replacing the Filter Valve

Save PXE 100 Setpoints

Selector Valve Motor/Encoder Replacement

Front Dispose Addition (for Bulk Oil Units)

Remove Selector Valve to ATO flex tube

Temp/Level Probe Fitting Replacement

Label Replacement Instructions

High Limit Protection Probe Installation (CE Version built prior to 5/2020, ALL Versions after)

High Limit Protection Probe Installation (UL Version built prior to 5/2020)

Menu Card Removal Replacement Instructions

Re-flashing Instructions

Save and Load Setpoint Instructions

PXE Pump Motor Installation

Flexible Line Replacement Kit (Formed Tube), (Standard, Bulk-Oil Fryer)

Flexible Line Replacement Kit (Formed Tube), (Standard, NON Bulk-Oil Fryer)

JIB Pump Retrofit

Velocity High Limit Adjustment Instructions

Reference

Specifications

Menu Structure

Heating Times

Product Racking Recommendations

Error Codes

PXE 100 Plumbing Diagrams

PXE 100 Wiring Diagrams

PXE 100 Inspection and Planned Maintenance

PXE 100 KFC Annual Inspection Certification